OmniLinkBridge/OmniLinkBridgeTest/MQTTTest.cs

249 lines
9.1 KiB
C#
Raw Permalink Normal View History

using System;
using System.Text;
using System.Collections.Generic;
using HAI_Shared;
using Microsoft.VisualStudio.TestTools.UnitTesting;
using OmniLinkBridge.MQTT;
using OmniLinkBridgeTest.Mock;
namespace OmniLinkBridgeTest
{
[TestClass]
public class MQTTTest
{
MockOmniLinkII omniLink;
MessageProcessor messageProcessor;
[TestInitialize]
public void Initialize()
{
omniLink = new MockOmniLinkII();
messageProcessor = new MessageProcessor(omniLink);
}
[TestMethod]
public void AreaCommandInvalid()
{
SendCommandEventArgs actual = null;
omniLink.OnSendCommand += (sender, e) => { actual = e; };
// Invalid command
messageProcessor.Process($"omnilink/area1/command", "disarmed");
Assert.IsNull(actual);
// Out of range
messageProcessor.Process($"omnilink/area9/command", "disarm");
Assert.IsNull(actual);
}
[TestMethod]
public void AreaCommand()
{
void check(ushort id, string payload, enuUnitCommand command)
{
SendCommandEventArgs actual = null;
omniLink.OnSendCommand += (sender, e) => { actual = e; };
messageProcessor.Process($"omnilink/area{id}/command", payload);
SendCommandEventArgs expected = new SendCommandEventArgs()
{
Cmd = command,
Par = 0,
Pr2 = id
};
Assert.AreEqual(expected, actual);
}
// First area standard format
check(1, "disarm", enuUnitCommand.SecurityOff);
check(1, "arm_home", enuUnitCommand.SecurityDay);
check(1, "arm_away", enuUnitCommand.SecurityAway);
check(1, "arm_night", enuUnitCommand.SecurityNight);
check(1, "arm_home_instant", enuUnitCommand.SecurityDyi);
check(1, "arm_night_delay", enuUnitCommand.SecurityNtd);
check(1, "arm_vacation", enuUnitCommand.SecurityVac);
// Last area with case check
check(8, "DISARM", enuUnitCommand.SecurityOff);
}
[TestMethod]
public void ZoneCommand()
{
void check(ushort id, string payload, enuUnitCommand command)
{
SendCommandEventArgs actual = null;
omniLink.OnSendCommand += (sender, e) => { actual = e; };
messageProcessor.Process($"omnilink/zone{id}/command", payload);
SendCommandEventArgs expected = new SendCommandEventArgs()
{
Cmd = command,
Par = 0,
Pr2 = id
};
Assert.AreEqual(expected, actual);
}
check(1, "bypass", enuUnitCommand.Bypass);
check(1, "restore", enuUnitCommand.Restore);
check(2, "BYPASS", enuUnitCommand.Bypass);
}
[TestMethod]
public void UnitCommand()
{
void check(ushort id, string payload, enuUnitCommand command)
{
SendCommandEventArgs actual = null;
omniLink.OnSendCommand += (sender, e) => { actual = e; };
messageProcessor.Process($"omnilink/unit{id}/command", payload);
SendCommandEventArgs expected = new SendCommandEventArgs()
{
Cmd = command,
Par = 0,
Pr2 = id
};
Assert.AreEqual(expected, actual);
}
check(1, "ON", enuUnitCommand.On);
omniLink.Controller.Units[1].Status = 1;
check(1, "OFF", enuUnitCommand.Off);
check(2, "on", enuUnitCommand.On);
}
[TestMethod]
public void UnitLevelCommand()
{
void check(ushort id, string payload, enuUnitCommand command, int level)
{
SendCommandEventArgs actual = null;
omniLink.OnSendCommand += (sender, e) => { actual = e; };
messageProcessor.Process($"omnilink/unit{id}/brightness_command", payload);
SendCommandEventArgs expected = new SendCommandEventArgs()
{
Cmd = command,
Par = (byte)level,
Pr2 = id
};
Assert.AreEqual(expected, actual);
}
check(1, "50", enuUnitCommand.Level, 50);
}
[TestMethod]
public void ThermostatModeCommandInvalid()
{
SendCommandEventArgs actual = null;
omniLink.OnSendCommand += (sender, e) => { actual = e; };
omniLink.Controller.Thermostats[1].Type = enuThermostatType.HeatCool;
messageProcessor.Process($"omnilink/thermostat1/mode_command", "auto");
Assert.IsNull(actual);
omniLink.Controller.Thermostats[1].Type = enuThermostatType.CoolOnly;
messageProcessor.Process($"omnilink/thermostat1/mode_command", "auto");
Assert.IsNull(actual);
messageProcessor.Process($"omnilink/thermostat1/mode_command", "heat");
Assert.IsNull(actual);
omniLink.Controller.Thermostats[1].Type = enuThermostatType.HeatOnly;
messageProcessor.Process($"omnilink/thermostat1/mode_command", "auto");
Assert.IsNull(actual);
messageProcessor.Process($"omnilink/thermostat1/mode_command", "cool");
Assert.IsNull(actual);
}
[TestMethod]
public void ThermostatModeCommand()
{
void check(ushort id, string payload, enuUnitCommand command, int mode)
{
SendCommandEventArgs actual = null;
omniLink.OnSendCommand += (sender, e) => { actual = e; };
messageProcessor.Process($"omnilink/thermostat{id}/mode_command", payload);
SendCommandEventArgs expected = new SendCommandEventArgs()
{
Cmd = command,
Par = (byte)mode,
Pr2 = id
};
Assert.AreEqual(expected, actual);
}
omniLink.Controller.Thermostats[1].Type = enuThermostatType.AutoHeatCool;
check(1, "auto", enuUnitCommand.Mode, (int)enuThermostatMode.Auto);
check(1, "cool", enuUnitCommand.Mode, (int)enuThermostatMode.Cool);
check(1, "heat", enuUnitCommand.Mode, (int)enuThermostatMode.Heat);
check(1, "off", enuUnitCommand.Mode, (int)enuThermostatMode.Off);
omniLink.Controller.Thermostats[1].Type = enuThermostatType.HeatCool;
check(1, "cool", enuUnitCommand.Mode, (int)enuThermostatMode.Cool);
check(1, "heat", enuUnitCommand.Mode, (int)enuThermostatMode.Heat);
check(1, "off", enuUnitCommand.Mode, (int)enuThermostatMode.Off);
omniLink.Controller.Thermostats[1].Type = enuThermostatType.CoolOnly;
check(1, "cool", enuUnitCommand.Mode, (int)enuThermostatMode.Cool);
check(1, "off", enuUnitCommand.Mode, (int)enuThermostatMode.Off);
omniLink.Controller.Thermostats[1].Type = enuThermostatType.HeatOnly;
check(1, "heat", enuUnitCommand.Mode, (int)enuThermostatMode.Heat);
check(1, "off", enuUnitCommand.Mode, (int)enuThermostatMode.Off);
}
[TestMethod]
public void ButtonCommand()
{
void check(ushort id, string payload, enuUnitCommand command)
{
SendCommandEventArgs actual = null;
omniLink.OnSendCommand += (sender, e) => { actual = e; };
messageProcessor.Process($"omnilink/button{id}/command", payload);
SendCommandEventArgs expected = new SendCommandEventArgs()
{
Cmd = command,
Par = 0,
Pr2 = id
};
Assert.AreEqual(expected, actual);
}
check(1, "ON", enuUnitCommand.Button);
check(1, "on", enuUnitCommand.Button);
}
[TestMethod]
public void MessageCommand()
{
void check(ushort id, string payload, enuUnitCommand command, byte par)
{
SendCommandEventArgs actual = null;
omniLink.OnSendCommand += (sender, e) => { actual = e; };
messageProcessor.Process($"omnilink/message{id}/command", payload);
SendCommandEventArgs expected = new SendCommandEventArgs()
{
Cmd = command,
Par = par,
Pr2 = id
};
Assert.AreEqual(expected, actual);
}
check(1, "show", enuUnitCommand.ShowMsgWBeep, 0);
check(1, "show_no_beep", enuUnitCommand.ShowMsgNoBeep, 1);
check(1, "show_no_beep_or_led", enuUnitCommand.ShowMsgNoBeep, 2);
check(1, "clear", enuUnitCommand.ClearMsg, 0);
check(2, "SHOW", enuUnitCommand.ShowMsgWBeep, 0);
}
}
}