using System;
|
|||
|
using System.Text;
|
|||
|
using System.Collections.Generic;
|
|||
|
using HAI_Shared;
|
|||
|
using Microsoft.VisualStudio.TestTools.UnitTesting;
|
|||
|
using OmniLinkBridge.MQTT;
|
|||
|
using OmniLinkBridgeTest.Mock;
|
|||
|
|
|||
|
namespace OmniLinkBridgeTest
|
|||
|
{
|
|||
|
[TestClass]
|
|||
|
public class MQTTTest
|
|||
|
{
|
|||
|
MockOmniLinkII omniLink;
|
|||
|
MessageProcessor messageProcessor;
|
|||
|
|
|||
|
[TestInitialize]
|
|||
|
public void Initialize()
|
|||
|
{
|
|||
|
omniLink = new MockOmniLinkII();
|
|||
|
messageProcessor = new MessageProcessor(omniLink);
|
|||
|
}
|
|||
|
|
|||
|
[TestMethod]
|
|||
|
public void AreaCommandInvalid()
|
|||
|
{
|
|||
|
SendCommandEventArgs actual = null;
|
|||
|
omniLink.OnSendCommand += (sender, e) => { actual = e; };
|
|||
|
|
|||
|
// Invalid command
|
|||
|
messageProcessor.Process($"omnilink/area1/command", "disarmed");
|
|||
|
Assert.IsNull(actual);
|
|||
|
|
|||
|
// Out of range
|
|||
|
messageProcessor.Process($"omnilink/area9/command", "disarm");
|
|||
|
Assert.IsNull(actual);
|
|||
|
}
|
|||
|
|
|||
|
[TestMethod]
|
|||
|
public void AreaCommand()
|
|||
|
{
|
|||
|
void check(ushort id, string payload, enuUnitCommand command)
|
|||
|
{
|
|||
|
SendCommandEventArgs actual = null;
|
|||
|
omniLink.OnSendCommand += (sender, e) => { actual = e; };
|
|||
|
messageProcessor.Process($"omnilink/area{id}/command", payload);
|
|||
|
SendCommandEventArgs expected = new SendCommandEventArgs()
|
|||
|
{
|
|||
|
Cmd = command,
|
|||
|
Par = 0,
|
|||
|
Pr2 = id
|
|||
|
};
|
|||
|
Assert.AreEqual(expected, actual);
|
|||
|
}
|
|||
|
|
|||
|
// First area standard format
|
|||
|
check(1, "disarm", enuUnitCommand.SecurityOff);
|
|||
|
check(1, "arm_home", enuUnitCommand.SecurityDay);
|
|||
|
check(1, "arm_away", enuUnitCommand.SecurityAway);
|
|||
|
check(1, "arm_night", enuUnitCommand.SecurityNight);
|
|||
|
check(1, "arm_home_instant", enuUnitCommand.SecurityDyi);
|
|||
|
check(1, "arm_night_delay", enuUnitCommand.SecurityNtd);
|
|||
|
check(1, "arm_vacation", enuUnitCommand.SecurityVac);
|
|||
|
|
|||
|
// Last area with case check
|
|||
|
check(8, "DISARM", enuUnitCommand.SecurityOff);
|
|||
|
}
|
|||
|
|
|||
|
[TestMethod]
|
|||
|
public void ZoneCommand()
|
|||
|
{
|
|||
|
void check(ushort id, string payload, enuUnitCommand command)
|
|||
|
{
|
|||
|
SendCommandEventArgs actual = null;
|
|||
|
omniLink.OnSendCommand += (sender, e) => { actual = e; };
|
|||
|
messageProcessor.Process($"omnilink/zone{id}/command", payload);
|
|||
|
SendCommandEventArgs expected = new SendCommandEventArgs()
|
|||
|
{
|
|||
|
Cmd = command,
|
|||
|
Par = 0,
|
|||
|
Pr2 = id
|
|||
|
};
|
|||
|
Assert.AreEqual(expected, actual);
|
|||
|
}
|
|||
|
|
|||
|
check(1, "bypass", enuUnitCommand.Bypass);
|
|||
|
check(1, "restore", enuUnitCommand.Restore);
|
|||
|
|
|||
|
check(2, "BYPASS", enuUnitCommand.Bypass);
|
|||
|
}
|
|||
|
|
|||
|
[TestMethod]
|
|||
|
public void UnitCommand()
|
|||
|
{
|
|||
|
void check(ushort id, string payload, enuUnitCommand command)
|
|||
|
{
|
|||
|
SendCommandEventArgs actual = null;
|
|||
|
omniLink.OnSendCommand += (sender, e) => { actual = e; };
|
|||
|
messageProcessor.Process($"omnilink/unit{id}/command", payload);
|
|||
|
SendCommandEventArgs expected = new SendCommandEventArgs()
|
|||
|
{
|
|||
|
Cmd = command,
|
|||
|
Par = 0,
|
|||
|
Pr2 = id
|
|||
|
};
|
|||
|
Assert.AreEqual(expected, actual);
|
|||
|
}
|
|||
|
|
|||
|
check(1, "ON", enuUnitCommand.On);
|
|||
|
omniLink.Controller.Units[1].Status = 1;
|
|||
|
check(1, "OFF", enuUnitCommand.Off);
|
|||
|
|
|||
|
check(2, "on", enuUnitCommand.On);
|
|||
|
}
|
|||
|
|
|||
|
[TestMethod]
|
|||
|
public void UnitLevelCommand()
|
|||
|
{
|
|||
|
void check(ushort id, string payload, enuUnitCommand command, int level)
|
|||
|
{
|
|||
|
SendCommandEventArgs actual = null;
|
|||
|
omniLink.OnSendCommand += (sender, e) => { actual = e; };
|
|||
|
messageProcessor.Process($"omnilink/unit{id}/brightness_command", payload);
|
|||
|
SendCommandEventArgs expected = new SendCommandEventArgs()
|
|||
|
{
|
|||
|
Cmd = command,
|
|||
|
Par = (byte)level,
|
|||
|
Pr2 = id
|
|||
|
};
|
|||
|
Assert.AreEqual(expected, actual);
|
|||
|
}
|
|||
|
|
|||
|
check(1, "50", enuUnitCommand.Level, 50);
|
|||
|
}
|
|||
|
|
|||
|
[TestMethod]
|
|||
|
public void ButtonCommand()
|
|||
|
{
|
|||
|
void check(ushort id, string payload, enuUnitCommand command)
|
|||
|
{
|
|||
|
SendCommandEventArgs actual = null;
|
|||
|
omniLink.OnSendCommand += (sender, e) => { actual = e; };
|
|||
|
messageProcessor.Process($"omnilink/button{id}/command", payload);
|
|||
|
SendCommandEventArgs expected = new SendCommandEventArgs()
|
|||
|
{
|
|||
|
Cmd = command,
|
|||
|
Par = 0,
|
|||
|
Pr2 = id
|
|||
|
};
|
|||
|
Assert.AreEqual(expected, actual);
|
|||
|
}
|
|||
|
|
|||
|
check(1, "ON", enuUnitCommand.Button);
|
|||
|
check(1, "on", enuUnitCommand.Button);
|
|||
|
}
|
|||
|
}
|
|||
|
}
|
|||
|
|
|||
|
|