using HAI_Shared; using Microsoft.VisualStudio.TestTools.UnitTesting; using OmniLinkBridge; using OmniLinkBridge.Modules; using OmniLinkBridge.MQTT; using OmniLinkBridgeTest.Mock; using Serilog; using System; using System.Collections.Concurrent; using System.Collections.Generic; namespace OmniLinkBridgeTest { [TestClass] public class MQTTTest { MockOmniLinkII omniLink; MessageProcessor messageProcessor; [TestInitialize] public void Initialize() { string log_format = "{Timestamp:yyyy-MM-dd HH:mm:ss} [{SourceContext} {Level:u3}] {Message:lj}{NewLine}{Exception}"; var log_config = new LoggerConfiguration() .MinimumLevel.Verbose() .Enrich.FromLogContext() .WriteTo.Console(outputTemplate: log_format); Log.Logger = log_config.CreateLogger(); Dictionary audioSources = new Dictionary { { "Radio", 1 }, { "Streaming", 2 }, { "TV", 4 } }; omniLink = new MockOmniLinkII(); messageProcessor = new MessageProcessor(omniLink, audioSources, 8); omniLink.Controller.Units[395].Type = enuOL2UnitType.Flag; } [TestMethod] public void AreaCommandInvalid() { SendCommandEventArgs actual = null; omniLink.OnSendCommand += (sender, e) => { actual = e; }; // Invalid command messageProcessor.Process($"omnilink/area1/command", "disarmed"); Assert.IsNull(actual); // Out of range messageProcessor.Process($"omnilink/area9/command", "disarm"); Assert.IsNull(actual); } [TestMethod] public void AreaCommand() { void check(ushort id, int code, string payload, enuUnitCommand command) { SendCommandEventArgs actual = null; omniLink.OnSendCommand += (sender, e) => { actual = e; }; messageProcessor.Process($"omnilink/area{id}/command", payload); SendCommandEventArgs expected = new SendCommandEventArgs() { Cmd = command, Par = (byte)code, Pr2 = id }; Assert.AreEqual(expected, actual); } // Standard format check(1, 0, "disarm", enuUnitCommand.SecurityOff); check(1, 0, "arm_home", enuUnitCommand.SecurityDay); check(1, 0, "arm_away", enuUnitCommand.SecurityAway); check(1, 0, "arm_night", enuUnitCommand.SecurityNight); check(1, 0, "arm_home_instant", enuUnitCommand.SecurityDyi); check(1, 0, "arm_night_delay", enuUnitCommand.SecurityNtd); check(1, 0, "arm_vacation", enuUnitCommand.SecurityVac); // Check all areas check(0, 0, "disarm", enuUnitCommand.SecurityOff); // Check with optional code check(1, 1, "disarm,1", enuUnitCommand.SecurityOff); // Check case insensitivity check(8, 0, "DISARM", enuUnitCommand.SecurityOff); } [TestMethod] public void ZoneCommand() { void check(ushort id, int code, string payload, enuUnitCommand command, bool ensureNull = false) { SendCommandEventArgs actual = null; omniLink.OnSendCommand += (sender, e) => { actual = e; }; messageProcessor.Process($"omnilink/zone{id}/command", payload); SendCommandEventArgs expected = new SendCommandEventArgs() { Cmd = command, Par = (byte)code, Pr2 = id }; if (ensureNull) Assert.IsNull(actual); else Assert.AreEqual(expected, actual); } // Standard format check(1, 0, "bypass", enuUnitCommand.Bypass); check(1, 0, "restore", enuUnitCommand.Restore); // Check all zones check(0, 0, "restore", enuUnitCommand.Restore); // Not allowed to bypass all zones check(0, 0, "bypass", enuUnitCommand.Bypass, true); // Check with optional code check(1, 1, "bypass,1", enuUnitCommand.Bypass); // Check case insensitivity check(2, 0, "BYPASS", enuUnitCommand.Bypass); } [TestMethod] public void UnitCommand() { void check(ushort id, string payload, enuUnitCommand command) { SendCommandEventArgs actual = null; omniLink.OnSendCommand += (sender, e) => { actual = e; }; messageProcessor.Process($"omnilink/unit{id}/command", payload); SendCommandEventArgs expected = new SendCommandEventArgs() { Cmd = command, Par = 0, Pr2 = id }; Assert.AreEqual(expected, actual); } check(1, "ON", enuUnitCommand.On); omniLink.Controller.Units[1].Status = 1; check(1, "OFF", enuUnitCommand.Off); check(2, "on", enuUnitCommand.On); } [TestMethod] public void UnitFlagCommand() { void check(ushort id, string payload, enuUnitCommand command, int value) { SendCommandEventArgs actual = null; omniLink.OnSendCommand += (sender, e) => { actual = e; }; messageProcessor.Process($"omnilink/unit{id}/flag_command", payload); SendCommandEventArgs expected = new SendCommandEventArgs() { Cmd = command, Par = (byte)value, Pr2 = id }; Assert.AreEqual(expected, actual); } check(395, "0", enuUnitCommand.Set, 0); check(395, "1", enuUnitCommand.Set, 1); check(395, "255", enuUnitCommand.Set, 255); } [TestMethod] public void UnitLevelCommand() { void check(ushort id, string payload, enuUnitCommand command, int level) { SendCommandEventArgs actual = null; omniLink.OnSendCommand += (sender, e) => { actual = e; }; messageProcessor.Process($"omnilink/unit{id}/brightness_command", payload); SendCommandEventArgs expected = new SendCommandEventArgs() { Cmd = command, Par = (byte)level, Pr2 = id }; Assert.AreEqual(expected, actual); } check(1, "50", enuUnitCommand.Level, 50); } [TestMethod] public void ThermostatModeCommandInvalid() { SendCommandEventArgs actual = null; omniLink.OnSendCommand += (sender, e) => { actual = e; }; omniLink.Controller.Thermostats[1].Type = enuThermostatType.HeatCool; messageProcessor.Process($"omnilink/thermostat1/mode_command", "auto"); Assert.IsNull(actual); omniLink.Controller.Thermostats[1].Type = enuThermostatType.CoolOnly; messageProcessor.Process($"omnilink/thermostat1/mode_command", "auto"); Assert.IsNull(actual); messageProcessor.Process($"omnilink/thermostat1/mode_command", "heat"); Assert.IsNull(actual); omniLink.Controller.Thermostats[1].Type = enuThermostatType.HeatOnly; messageProcessor.Process($"omnilink/thermostat1/mode_command", "auto"); Assert.IsNull(actual); messageProcessor.Process($"omnilink/thermostat1/mode_command", "cool"); Assert.IsNull(actual); } [TestMethod] public void ThermostatModeCommand() { void check(ushort id, string payload, enuUnitCommand command, int mode) { SendCommandEventArgs actual = null; omniLink.OnSendCommand += (sender, e) => { actual = e; }; messageProcessor.Process($"omnilink/thermostat{id}/mode_command", payload); SendCommandEventArgs expected = new SendCommandEventArgs() { Cmd = command, Par = (byte)mode, Pr2 = id }; Assert.AreEqual(expected, actual); } omniLink.Controller.Thermostats[1].Type = enuThermostatType.AutoHeatCool; check(1, "auto", enuUnitCommand.Mode, (int)enuThermostatMode.Auto); check(1, "cool", enuUnitCommand.Mode, (int)enuThermostatMode.Cool); check(1, "heat", enuUnitCommand.Mode, (int)enuThermostatMode.Heat); check(1, "off", enuUnitCommand.Mode, (int)enuThermostatMode.Off); omniLink.Controller.Thermostats[1].Type = enuThermostatType.HeatCool; check(1, "cool", enuUnitCommand.Mode, (int)enuThermostatMode.Cool); check(1, "heat", enuUnitCommand.Mode, (int)enuThermostatMode.Heat); check(1, "off", enuUnitCommand.Mode, (int)enuThermostatMode.Off); omniLink.Controller.Thermostats[1].Type = enuThermostatType.CoolOnly; check(1, "cool", enuUnitCommand.Mode, (int)enuThermostatMode.Cool); check(1, "off", enuUnitCommand.Mode, (int)enuThermostatMode.Off); omniLink.Controller.Thermostats[1].Type = enuThermostatType.HeatOnly; check(1, "heat", enuUnitCommand.Mode, (int)enuThermostatMode.Heat); check(1, "off", enuUnitCommand.Mode, (int)enuThermostatMode.Off); } [TestMethod] public void ButtonCommand() { void check(ushort id, string payload, enuUnitCommand command) { SendCommandEventArgs actual = null; omniLink.OnSendCommand += (sender, e) => { actual = e; }; messageProcessor.Process($"omnilink/button{id}/command", payload); SendCommandEventArgs expected = new SendCommandEventArgs() { Cmd = command, Par = 0, Pr2 = id }; Assert.AreEqual(expected, actual); } check(1, "ON", enuUnitCommand.Button); check(1, "on", enuUnitCommand.Button); } [TestMethod] public void MessageCommand() { void check(ushort id, string payload, enuUnitCommand command, byte par) { SendCommandEventArgs actual = null; omniLink.OnSendCommand += (sender, e) => { actual = e; }; messageProcessor.Process($"omnilink/message{id}/command", payload); SendCommandEventArgs expected = new SendCommandEventArgs() { Cmd = command, Par = par, Pr2 = id }; Assert.AreEqual(expected, actual); } check(1, "show", enuUnitCommand.ShowMsgWBeep, 0); check(1, "show_no_beep", enuUnitCommand.ShowMsgNoBeep, 1); check(1, "show_no_beep_or_led", enuUnitCommand.ShowMsgNoBeep, 2); check(1, "clear", enuUnitCommand.ClearMsg, 0); check(2, "SHOW", enuUnitCommand.ShowMsgWBeep, 0); } [TestMethod] public void LockCommand() { void check(ushort id, string payload, enuUnitCommand command) { SendCommandEventArgs actual = null; omniLink.OnSendCommand += (sender, e) => { actual = e; }; messageProcessor.Process($"omnilink/lock{id}/command", payload); SendCommandEventArgs expected = new SendCommandEventArgs() { Cmd = command, Par = 0, Pr2 = id }; Assert.AreEqual(expected, actual); } check(1, "lock", enuUnitCommand.Lock); check(1, "unlock", enuUnitCommand.Unlock); // Check all locks check(0, "lock", enuUnitCommand.Lock); // Check case insensitivity check(2, "LOCK", enuUnitCommand.Lock); } [TestMethod] public void AudioCommand() { void check(ushort id, string payload, enuUnitCommand command, int value) { SendCommandEventArgs actual = null; omniLink.OnSendCommand += (sender, e) => { actual = e; }; messageProcessor.Process($"omnilink/audio{id}/command", payload); SendCommandEventArgs expected = new SendCommandEventArgs() { Cmd = command, Par = (byte)value, Pr2 = id }; Assert.AreEqual(expected, actual); } check(1, "ON", enuUnitCommand.AudioZone, 1); check(1, "OFF", enuUnitCommand.AudioZone, 0); check(2, "on", enuUnitCommand.AudioZone, 1); } [TestMethod] public void AudioMuteCommand() { void check(ushort id, string payload, enuUnitCommand command, int value) { SendCommandEventArgs actual = null; omniLink.OnSendCommand += (sender, e) => { actual = e; }; messageProcessor.Process($"omnilink/audio{id}/mute_command", payload); SendCommandEventArgs expected = new SendCommandEventArgs() { Cmd = command, Par = (byte)value, Pr2 = id }; Assert.AreEqual(expected, actual); } check(1, "ON", enuUnitCommand.AudioZone, 3); check(1, "OFF", enuUnitCommand.AudioZone, 2); Global.mqtt_audio_local_mute = true; omniLink.Controller.AudioZones[2].Volume = 50; check(2, "on", enuUnitCommand.AudioVolume, 0); check(2, "off", enuUnitCommand.AudioVolume, 50); omniLink.Controller.AudioZones[2].Volume = 0; check(2, "on", enuUnitCommand.AudioVolume, 0); check(2, "off", enuUnitCommand.AudioVolume, 10); } [TestMethod] public void AudioSourceCommand() { void check(ushort id, string payload, enuUnitCommand command, int value) { SendCommandEventArgs actual = null; omniLink.OnSendCommand += (sender, e) => { actual = e; }; messageProcessor.Process($"omnilink/audio{id}/source_command", payload); SendCommandEventArgs expected = new SendCommandEventArgs() { Cmd = command, Par = (byte)value, Pr2 = id }; Assert.AreEqual(expected, actual); } check(1, "Radio", enuUnitCommand.AudioSource, 1); check(1, "Streaming", enuUnitCommand.AudioSource, 2); check(2, "TV", enuUnitCommand.AudioSource, 4); } [TestMethod] public void AudioVolumeCommand() { void check(ushort id, string payload, enuUnitCommand command, int value) { SendCommandEventArgs actual = null; omniLink.OnSendCommand += (sender, e) => { actual = e; }; messageProcessor.Process($"omnilink/audio{id}/volume_command", payload); SendCommandEventArgs expected = new SendCommandEventArgs() { Cmd = command, Par = (byte)value, Pr2 = id }; Assert.AreEqual(expected, actual); } check(1, "100", enuUnitCommand.AudioVolume, 100); check(1, "75", enuUnitCommand.AudioVolume, 75); check(2, "0", enuUnitCommand.AudioVolume, 0); Global.mqtt_audio_volume_media_player = true; check(2, "1", enuUnitCommand.AudioVolume, 100); check(2, "0.75", enuUnitCommand.AudioVolume, 75); check(2, "0", enuUnitCommand.AudioVolume, 0); } } }