1.1.2 - Add min and max climate temperatures

- Update docker run command to use local time zone
- Improve area and zone MQTT support
- Add option to change MQTT prefix to support multiple instances
- Add detailed zone sensor and thermostat humidity sensor
- Add prefix for MQTT discovery entity name
- Request zone status update on area status change
This commit is contained in:
Ryan Wagoner 2018-10-23 23:51:05 -04:00
parent 78694b386d
commit 96093fbebd
13 changed files with 310 additions and 94 deletions

View file

@ -48,7 +48,9 @@ namespace OmniLinkBridge
public static int mqtt_port;
public static string mqtt_username;
public static string mqtt_password;
public static string mqtt_prefix;
public static string mqtt_discovery_prefix;
public static string mqtt_discovery_name_prefix;
public static HashSet<int> mqtt_discovery_ignore_zones;
public static HashSet<int> mqtt_discovery_ignore_units;
public static ConcurrentDictionary<int, OverrideZone> mqtt_discovery_override_zone;

View file

@ -8,6 +8,8 @@ namespace OmniLinkBridge.MQTT
{
public class Alarm : Device
{
public string basic_state_topic { get; set; }
public string command_topic { get; set; }
//public string code { get; set; } = string.Empty;

View file

@ -16,6 +16,9 @@ namespace OmniLinkBridge.MQTT
public string temperature_high_state_topic { get; set; }
public string temperature_high_command_topic { get; set; }
public string min_temp { get; set; } = "45";
public string max_temp { get; set; } = "95";
public string mode_state_topic { get; set; }
public string mode_command_topic { get; set; }
public List<string> modes { get; set; } = new List<string>(new string[] { "auto", "off", "cool", "heat" });

View file

@ -12,6 +12,6 @@ namespace OmniLinkBridge.MQTT
public string state_topic { get; set; }
public string availability_topic { get; set; } = "omnilink/status";
public string availability_topic { get; set; } = $"{Global.mqtt_prefix}/status";
}
}

View file

@ -11,19 +11,46 @@ namespace OmniLinkBridge.MQTT
{
public static string ToTopic(this clsArea area, Topic topic)
{
return $"omnilink/area{area.Number.ToString()}/{topic.ToString()}";
return $"{Global.mqtt_prefix}/area{area.Number.ToString()}/{topic.ToString()}";
}
public static Alarm ToConfig(this clsArea area)
{
Alarm ret = new Alarm();
ret.name = area.Name;
ret.state_topic = area.ToTopic(Topic.state);
ret.name = Global.mqtt_discovery_name_prefix + area.Name;
ret.state_topic = area.ToTopic(Topic.basic_state);
ret.command_topic = area.ToTopic(Topic.command);
return ret;
}
public static string ToState(this clsArea area)
{
if (area.AreaBurglaryAlarmText != "OK")
return "triggered";
else if (area.ExitTimer > 0)
return "pending";
switch (area.AreaMode)
{
case enuSecurityMode.Night:
return "armed_night";
case enuSecurityMode.NightDly:
return "armed_night_delay";
case enuSecurityMode.Day:
return "armed_home";
case enuSecurityMode.DayInst:
return "armed_home_instant";
case enuSecurityMode.Away:
return "armed_away";
case enuSecurityMode.Vacation:
return "armed_vacation";
case enuSecurityMode.Off:
default:
return "disarmed";
}
}
public static string ToBasicState(this clsArea area)
{
if (area.AreaBurglaryAlarmText != "OK")
return "triggered";
@ -49,15 +76,15 @@ namespace OmniLinkBridge.MQTT
public static string ToTopic(this clsZone zone, Topic topic)
{
return $"omnilink/zone{zone.Number.ToString()}/{topic.ToString()}";
return $"{Global.mqtt_prefix}/zone{zone.Number.ToString()}/{topic.ToString()}";
}
public static Sensor ToConfigTemp(this clsZone zone)
{
Sensor ret = new Sensor();
ret.name = zone.Name;
ret.name = $"{Global.mqtt_discovery_name_prefix}{zone.Name} Temp";
ret.device_class = Sensor.DeviceClass.temperature;
ret.state_topic = zone.ToTopic(Topic.state);
ret.state_topic = zone.ToTopic(Topic.current_temperature);
ret.unit_of_measurement = "°F";
return ret;
}
@ -65,17 +92,56 @@ namespace OmniLinkBridge.MQTT
public static Sensor ToConfigHumidity(this clsZone zone)
{
Sensor ret = new Sensor();
ret.name = zone.Name;
ret.name = $"{Global.mqtt_discovery_name_prefix}{zone.Name} Humidity";
ret.device_class = Sensor.DeviceClass.humidity;
ret.state_topic = zone.ToTopic(Topic.state);
ret.state_topic = zone.ToTopic(Topic.current_humidity);
ret.unit_of_measurement = "%";
return ret;
}
public static Sensor ToConfigSensor(this clsZone zone)
{
Sensor ret = new Sensor();
ret.name = Global.mqtt_discovery_name_prefix + zone.Name;
switch (zone.ZoneType)
{
case enuZoneType.EntryExit:
case enuZoneType.X2EntryDelay:
case enuZoneType.X4EntryDelay:
ret.icon = "mdi:door";
break;
case enuZoneType.Perimeter:
ret.icon = "mdi:window-closed";
break;
case enuZoneType.Tamper:
ret.icon = "mdi:shield";
break;
case enuZoneType.AwayInt:
case enuZoneType.NightInt:
ret.icon = "mdi:walk";
break;
case enuZoneType.Water:
ret.icon = "mdi:water";
break;
case enuZoneType.Fire:
ret.icon = "mdi:fire";
break;
case enuZoneType.Gas:
ret.icon = "mdi:gas-cylinder";
break;
}
ret.value_template = @"{{ value|replace(""_"", "" "")|title }}";
ret.state_topic = zone.ToTopic(Topic.state);
return ret;
}
public static BinarySensor ToConfig(this clsZone zone)
{
BinarySensor ret = new BinarySensor();
ret.name = zone.Name;
ret.name = Global.mqtt_discovery_name_prefix + zone.Name;
Global.mqtt_discovery_override_zone.TryGetValue(zone.Number, out OverrideZone override_zone);
@ -114,27 +180,40 @@ namespace OmniLinkBridge.MQTT
}
}
ret.state_topic = zone.ToTopic(Topic.state);
ret.state_topic = zone.ToTopic(Topic.basic_state);
return ret;
}
public static string ToState(this clsZone zone)
{
if (zone.IsTemperatureZone() || zone.IsHumidityZone())
return zone.TempText();
if (zone.Status.IsBitSet(5))
return "bypassed";
else if (zone.Status.IsBitSet(2))
return "tripped";
else if (zone.Status.IsBitSet(4))
return "armed";
else if (zone.Status.IsBitSet(1))
return "trouble";
else if (zone.Status.IsBitSet(0))
return "not_ready";
else
return "secure";
}
public static string ToBasicState(this clsZone zone)
{
return zone.Status.IsBitSet(0) ? "ON" : "OFF";
}
public static string ToTopic(this clsUnit unit, Topic topic)
{
return $"omnilink/unit{unit.Number.ToString()}/{topic.ToString()}";
return $"{Global.mqtt_prefix}/unit{unit.Number.ToString()}/{topic.ToString()}";
}
public static Light ToConfig(this clsUnit unit)
{
Light ret = new Light();
ret.name = unit.Name;
ret.name = Global.mqtt_discovery_name_prefix + unit.Name;
ret.state_topic = unit.ToTopic(Topic.state);
ret.command_topic = unit.ToTopic(Topic.command);
ret.brightness_state_topic = unit.ToTopic(Topic.brightness_state);
@ -145,7 +224,7 @@ namespace OmniLinkBridge.MQTT
public static Switch ToConfigSwitch(this clsUnit unit)
{
Switch ret = new Switch();
ret.name = unit.Name;
ret.name = Global.mqtt_discovery_name_prefix + unit.Name;
ret.state_topic = unit.ToTopic(Topic.state);
ret.command_topic = unit.ToTopic(Topic.command);
return ret;
@ -168,13 +247,23 @@ namespace OmniLinkBridge.MQTT
public static string ToTopic(this clsThermostat thermostat, Topic topic)
{
return $"omnilink/thermostat{thermostat.Number.ToString()}/{topic.ToString()}";
return $"{Global.mqtt_prefix}/thermostat{thermostat.Number.ToString()}/{topic.ToString()}";
}
public static Sensor ToConfigHumidity(this clsThermostat zone)
{
Sensor ret = new Sensor();
ret.name = Global.mqtt_discovery_name_prefix + zone.Name;
ret.device_class = Sensor.DeviceClass.humidity;
ret.state_topic = zone.ToTopic(Topic.current_humidity);
ret.unit_of_measurement = "%";
return ret;
}
public static Climate ToConfig(this clsThermostat thermostat)
{
Climate ret = new Climate();
ret.name = thermostat.Name;
ret.name = Global.mqtt_discovery_name_prefix + thermostat.Name;
ret.current_temperature_topic = thermostat.ToTopic(Topic.current_temperature);
ret.temperature_low_state_topic = thermostat.ToTopic(Topic.temperature_heat_state);
@ -208,13 +297,13 @@ namespace OmniLinkBridge.MQTT
public static string ToTopic(this clsButton button, Topic topic)
{
return $"omnilink/button{button.Number.ToString()}/{topic.ToString()}";
return $"{Global.mqtt_prefix}/button{button.Number.ToString()}/{topic.ToString()}";
}
public static Switch ToConfig(this clsButton button)
{
Switch ret = new Switch();
ret.name = button.Name;
ret.name = Global.mqtt_discovery_name_prefix + button.Name;
ret.state_topic = button.ToTopic(Topic.state);
ret.command_topic = button.ToTopic(Topic.command);
return ret;

View file

@ -20,7 +20,13 @@ namespace OmniLinkBridge.MQTT
[JsonProperty(NullValueHandling = NullValueHandling.Ignore)]
public DeviceClass? device_class { get; set; }
[JsonProperty(NullValueHandling = NullValueHandling.Ignore)]
public string icon { get; set; }
[JsonProperty(NullValueHandling = NullValueHandling.Ignore)]
public string unit_of_measurement { get; set; }
[JsonProperty(NullValueHandling = NullValueHandling.Ignore)]
public string value_template { get; set; }
}
}

View file

@ -25,6 +25,8 @@ namespace OmniLinkBridge.MQTT
public static Topic state { get { return new Topic("state"); } }
public static Topic command { get { return new Topic("command"); } }
public static Topic basic_state { get { return new Topic("basic_state"); } }
public static Topic brightness_state { get { return new Topic("brightness_state"); } }
public static Topic brightness_command { get { return new Topic("brightness_command"); } }

View file

@ -23,7 +23,7 @@ namespace OmniLinkBridge.Modules
private OmniLinkII OmniLink { get; set; }
private IManagedMqttClient MqttClient { get; set; }
private Regex regexTopic = new Regex("omnilink/([A-Za-z]+)([0-9]+)/(.*)", RegexOptions.Compiled);
private Regex regexTopic = new Regex(Global.mqtt_prefix + "/([A-Za-z]+)([0-9]+)/(.*)", RegexOptions.Compiled);
private readonly AutoResetEvent trigger = new AutoResetEvent(false);
@ -59,20 +59,20 @@ namespace OmniLinkBridge.Modules
MqttClient.ApplicationMessageReceived += MqttClient_ApplicationMessageReceived;
MqttClient.SubscribeAsync(new TopicFilterBuilder().WithTopic("omnilink/+/" + Topic.command).Build());
MqttClient.SubscribeAsync(new TopicFilterBuilder().WithTopic("omnilink/+/" + Topic.brightness_command).Build());
MqttClient.SubscribeAsync(new TopicFilterBuilder().WithTopic("omnilink/+/" + Topic.temperature_heat_command).Build());
MqttClient.SubscribeAsync(new TopicFilterBuilder().WithTopic("omnilink/+/" + Topic.temperature_cool_command).Build());
MqttClient.SubscribeAsync(new TopicFilterBuilder().WithTopic("omnilink/+/" + Topic.humidify_command).Build());
MqttClient.SubscribeAsync(new TopicFilterBuilder().WithTopic("omnilink/+/" + Topic.dehumidify_command).Build());
MqttClient.SubscribeAsync(new TopicFilterBuilder().WithTopic("omnilink/+/" + Topic.mode_command).Build());
MqttClient.SubscribeAsync(new TopicFilterBuilder().WithTopic("omnilink/+/" + Topic.fan_mode_command).Build());
MqttClient.SubscribeAsync(new TopicFilterBuilder().WithTopic("omnilink/+/" + Topic.hold_command).Build());
MqttClient.SubscribeAsync(new TopicFilterBuilder().WithTopic($"{Global.mqtt_prefix}/+/{Topic.command}").Build());
MqttClient.SubscribeAsync(new TopicFilterBuilder().WithTopic($"{Global.mqtt_prefix}/+/{Topic.brightness_command}").Build());
MqttClient.SubscribeAsync(new TopicFilterBuilder().WithTopic($"{Global.mqtt_prefix}/+/{Topic.temperature_heat_command}").Build());
MqttClient.SubscribeAsync(new TopicFilterBuilder().WithTopic($"{Global.mqtt_prefix}/+/{Topic.temperature_cool_command}").Build());
MqttClient.SubscribeAsync(new TopicFilterBuilder().WithTopic($"{Global.mqtt_prefix}/+/{Topic.humidify_command}").Build());
MqttClient.SubscribeAsync(new TopicFilterBuilder().WithTopic($"{Global.mqtt_prefix}/+/{Topic.dehumidify_command}").Build());
MqttClient.SubscribeAsync(new TopicFilterBuilder().WithTopic($"{Global.mqtt_prefix}/+/{Topic.mode_command}").Build());
MqttClient.SubscribeAsync(new TopicFilterBuilder().WithTopic($"{Global.mqtt_prefix}/+/{Topic.fan_mode_command}").Build());
MqttClient.SubscribeAsync(new TopicFilterBuilder().WithTopic($"{Global.mqtt_prefix}/+/{Topic.hold_command}").Build());
// Wait until shutdown
trigger.WaitOne();
MqttClient.PublishAsync("omnilink/status", "offline", MqttQualityOfServiceLevel.AtMostOnce, true);
MqttClient.PublishAsync($"{Global.mqtt_prefix}/status", "offline", MqttQualityOfServiceLevel.AtMostOnce, true);
}
private void MqttClient_ApplicationMessageReceived(object sender, MqttApplicationMessageReceivedEventArgs e)
@ -90,6 +90,10 @@ namespace OmniLinkBridge.Modules
{
ProcessAreaReceived(OmniLink.Controller.Areas[areaId], match.Groups[3].Value, payload);
}
if (match.Groups[1].Value == "zone" && ushort.TryParse(match.Groups[2].Value, out ushort zoneId) && zoneId < OmniLink.Controller.Zones.Count)
{
ProcessZoneReceived(OmniLink.Controller.Zones[zoneId], match.Groups[3].Value, payload);
}
else if (match.Groups[1].Value == "unit" && ushort.TryParse(match.Groups[2].Value, out ushort unitId) && unitId < OmniLink.Controller.Units.Count)
{
ProcessUnitReceived(OmniLink.Controller.Units[unitId], match.Groups[3].Value, payload);
@ -108,38 +112,58 @@ namespace OmniLinkBridge.Modules
{
if (string.Compare(command, Topic.command.ToString()) == 0)
{
switch(payload)
if(string.Compare(payload, "arm_home", true) == 0)
{
case "ARM_HOME":
log.Debug("SetArea: " + area.Number + " to home");
OmniLink.Controller.SendCommand(enuUnitCommand.SecurityDay, 0, (ushort)area.Number);
break;
case "ARM_AWAY":
}
else if (string.Compare(payload, "arm_away", true) == 0)
{
log.Debug("SetArea: " + area.Number + " to away");
OmniLink.Controller.SendCommand(enuUnitCommand.SecurityAway, 0, (ushort)area.Number);
break;
case "ARM_NIGHT":
}
else if (string.Compare(payload, "arm_night", true) == 0)
{
log.Debug("SetArea: " + area.Number + " to night");
OmniLink.Controller.SendCommand(enuUnitCommand.SecurityNight, 0, (ushort)area.Number);
break;
case "DISARM":
}
else if (string.Compare(payload, "disarm", true) == 0)
{
log.Debug("SetArea: " + area.Number + " to disarm");
OmniLink.Controller.SendCommand(enuUnitCommand.SecurityOff, 0, (ushort)area.Number);
break;
}
// The below aren't supported by Home Assistant
case "ARM_HOME_INSTANT":
else if (string.Compare(payload, "arm_home_instant", true) == 0)
{
log.Debug("SetArea: " + area.Number + " to home instant");
OmniLink.Controller.SendCommand(enuUnitCommand.SecurityDyi, 0, (ushort)area.Number);
break;
case "ARM_NIGHT_DELAY":
}
else if (string.Compare(payload, "arm_night_delay", true) == 0)
{
log.Debug("SetArea: " + area.Number + " to night delay");
OmniLink.Controller.SendCommand(enuUnitCommand.SecurityNtd, 0, (ushort)area.Number);
break;
case "ARM_VACATION":
}
else if (string.Compare(payload, "arm_vacation", true) == 0)
{
log.Debug("SetArea: " + area.Number + " to vacation");
OmniLink.Controller.SendCommand(enuUnitCommand.SecurityVac, 0, (ushort)area.Number);
break;
}
}
}
private void ProcessZoneReceived(clsZone zone, string command, string payload)
{
if (string.Compare(command, Topic.command.ToString()) == 0)
{
if (string.Compare(payload, "bypass", true) == 0)
{
log.Debug("SetZone: " + zone.Number + " to " + payload);
OmniLink.Controller.SendCommand(enuUnitCommand.Bypass, 0, (ushort)zone.Number);
}
else if (string.Compare(payload, "restore", true) == 0)
{
log.Debug("SetZone: " + zone.Number + " to " + payload);
OmniLink.Controller.SendCommand(enuUnitCommand.Restore, 0, (ushort)zone.Number);
}
}
}
@ -232,7 +256,7 @@ namespace OmniLinkBridge.Modules
{
PublishConfig();
MqttClient.PublishAsync("omnilink/status", "online", MqttQualityOfServiceLevel.AtMostOnce, true);
MqttClient.PublishAsync($"{Global.mqtt_prefix}/status", "online", MqttQualityOfServiceLevel.AtMostOnce, true);
}
private void PublishConfig()
@ -254,13 +278,13 @@ namespace OmniLinkBridge.Modules
if (area.DefaultProperties == true)
{
MqttClient.PublishAsync($"{Global.mqtt_discovery_prefix}/alarm_control_panel/omnilink/area{i.ToString()}/config", null, MqttQualityOfServiceLevel.AtMostOnce, true);
MqttClient.PublishAsync($"{Global.mqtt_discovery_prefix}/alarm_control_panel/{Global.mqtt_prefix}/area{i.ToString()}/config", null, MqttQualityOfServiceLevel.AtMostOnce, true);
continue;
}
PublishAreaState(area);
MqttClient.PublishAsync($"{Global.mqtt_discovery_prefix}/alarm_control_panel/omnilink/area{i.ToString()}/config",
MqttClient.PublishAsync($"{Global.mqtt_discovery_prefix}/alarm_control_panel/{Global.mqtt_prefix}/area{i.ToString()}/config",
JsonConvert.SerializeObject(area.ToConfig()), MqttQualityOfServiceLevel.AtMostOnce, true);
}
}
@ -275,28 +299,26 @@ namespace OmniLinkBridge.Modules
if (zone.DefaultProperties == true || Global.mqtt_discovery_ignore_zones.Contains(zone.Number))
{
MqttClient.PublishAsync($"{Global.mqtt_discovery_prefix}/sensor/omnilink/zone{i.ToString()}/config", null, MqttQualityOfServiceLevel.AtMostOnce, true);
MqttClient.PublishAsync($"{Global.mqtt_discovery_prefix}/binary_sensor/omnilink/zone{i.ToString()}/config", null, MqttQualityOfServiceLevel.AtMostOnce, true);
MqttClient.PublishAsync($"{Global.mqtt_discovery_prefix}/binary_sensor/{Global.mqtt_prefix}/zone{i.ToString()}/config", null, MqttQualityOfServiceLevel.AtMostOnce, true);
MqttClient.PublishAsync($"{Global.mqtt_discovery_prefix}/sensor/{Global.mqtt_prefix}/zone{i.ToString()}/config", null, MqttQualityOfServiceLevel.AtMostOnce, true);
MqttClient.PublishAsync($"{Global.mqtt_discovery_prefix}/sensor/{Global.mqtt_prefix}/zone{i.ToString()}temp/config", null, MqttQualityOfServiceLevel.AtMostOnce, true);
MqttClient.PublishAsync($"{Global.mqtt_discovery_prefix}/sensor/{Global.mqtt_prefix}/zone{i.ToString()}humidity/config", null, MqttQualityOfServiceLevel.AtMostOnce, true);
continue;
}
PublishZoneState(zone);
if (zone.IsTemperatureZone())
{
MqttClient.PublishAsync($"{Global.mqtt_discovery_prefix}/sensor/omnilink/zone{i.ToString()}/config",
JsonConvert.SerializeObject(zone.ToConfigTemp()), MqttQualityOfServiceLevel.AtMostOnce, true);
}
else if (zone.IsHumidityZone())
{
MqttClient.PublishAsync($"{Global.mqtt_discovery_prefix}/sensor/omnilink/zone{i.ToString()}/config",
JsonConvert.SerializeObject(zone.ToConfigHumidity()), MqttQualityOfServiceLevel.AtMostOnce, true);
}
else
{
MqttClient.PublishAsync($"{Global.mqtt_discovery_prefix}/binary_sensor/omnilink/zone{i.ToString()}/config",
MqttClient.PublishAsync($"{Global.mqtt_discovery_prefix}/binary_sensor/{Global.mqtt_prefix}/zone{i.ToString()}/config",
JsonConvert.SerializeObject(zone.ToConfig()), MqttQualityOfServiceLevel.AtMostOnce, true);
}
MqttClient.PublishAsync($"{Global.mqtt_discovery_prefix}/sensor/{Global.mqtt_prefix}/zone{i.ToString()}/config",
JsonConvert.SerializeObject(zone.ToConfigSensor()), MqttQualityOfServiceLevel.AtMostOnce, true);
if (zone.IsTemperatureZone())
MqttClient.PublishAsync($"{Global.mqtt_discovery_prefix}/sensor/{Global.mqtt_prefix}/zone{i.ToString()}temp/config",
JsonConvert.SerializeObject(zone.ToConfigTemp()), MqttQualityOfServiceLevel.AtMostOnce, true);
else if (zone.IsHumidityZone())
MqttClient.PublishAsync($"{Global.mqtt_discovery_prefix}/sensor/{Global.mqtt_prefix}/zone{i.ToString()}humidity/config",
JsonConvert.SerializeObject(zone.ToConfigHumidity()), MqttQualityOfServiceLevel.AtMostOnce, true);
}
}
@ -312,13 +334,13 @@ namespace OmniLinkBridge.Modules
if (unit.DefaultProperties == true || Global.mqtt_discovery_ignore_units.Contains(unit.Number))
{
MqttClient.PublishAsync($"{Global.mqtt_discovery_prefix}/{type}/omnilink/unit{i.ToString()}/config", null, MqttQualityOfServiceLevel.AtMostOnce, true);
MqttClient.PublishAsync($"{Global.mqtt_discovery_prefix}/{type}/{Global.mqtt_prefix}/unit{i.ToString()}/config", null, MqttQualityOfServiceLevel.AtMostOnce, true);
continue;
}
PublishUnitState(unit);
MqttClient.PublishAsync($"{Global.mqtt_discovery_prefix}/{type}/omnilink/unit{i.ToString()}/config",
MqttClient.PublishAsync($"{Global.mqtt_discovery_prefix}/{type}/{Global.mqtt_prefix}/unit{i.ToString()}/config",
JsonConvert.SerializeObject(unit.ToConfig()), MqttQualityOfServiceLevel.AtMostOnce, true);
}
}
@ -333,14 +355,17 @@ namespace OmniLinkBridge.Modules
if (thermostat.DefaultProperties == true)
{
MqttClient.PublishAsync($"{Global.mqtt_discovery_prefix}/climate/omnilink/thermostat{i.ToString()}/config", null, MqttQualityOfServiceLevel.AtMostOnce, true);
MqttClient.PublishAsync($"{Global.mqtt_discovery_prefix}/climate/{Global.mqtt_prefix}/thermostat{i.ToString()}/config", null, MqttQualityOfServiceLevel.AtMostOnce, true);
MqttClient.PublishAsync($"{Global.mqtt_discovery_prefix}/sensor/{Global.mqtt_prefix}/thermostat{i.ToString()}humidity/config", null, MqttQualityOfServiceLevel.AtMostOnce, true);
continue;
}
PublishThermostatState(thermostat);
MqttClient.PublishAsync($"{Global.mqtt_discovery_prefix}/climate/omnilink/thermostat{i.ToString()}/config",
MqttClient.PublishAsync($"{Global.mqtt_discovery_prefix}/climate/{Global.mqtt_prefix}/thermostat{i.ToString()}/config",
JsonConvert.SerializeObject(thermostat.ToConfig()), MqttQualityOfServiceLevel.AtMostOnce, true);
MqttClient.PublishAsync($"{Global.mqtt_discovery_prefix}/sensor/{Global.mqtt_prefix}/thermostat{i.ToString()}humidity/config",
JsonConvert.SerializeObject(thermostat.ToConfigHumidity()), MqttQualityOfServiceLevel.AtMostOnce, true);
}
}
@ -354,14 +379,14 @@ namespace OmniLinkBridge.Modules
if (button.DefaultProperties == true)
{
MqttClient.PublishAsync($"{Global.mqtt_discovery_prefix}/switch/omnilink/button{i.ToString()}/config", null, MqttQualityOfServiceLevel.AtMostOnce, true);
MqttClient.PublishAsync($"{Global.mqtt_discovery_prefix}/switch/{Global.mqtt_prefix}/button{i.ToString()}/config", null, MqttQualityOfServiceLevel.AtMostOnce, true);
continue;
}
// Buttons are always off
MqttClient.PublishAsync(button.ToTopic(Topic.state), "OFF", MqttQualityOfServiceLevel.AtMostOnce, true);
MqttClient.PublishAsync($"{Global.mqtt_discovery_prefix}/switch/omnilink/button{i.ToString()}/config",
MqttClient.PublishAsync($"{Global.mqtt_discovery_prefix}/switch/{Global.mqtt_prefix}/button{i.ToString()}/config",
JsonConvert.SerializeObject(button.ToConfig()), MqttQualityOfServiceLevel.AtMostOnce, true);
}
}
@ -369,6 +394,31 @@ namespace OmniLinkBridge.Modules
private void Omnilink_OnAreaStatus(object sender, AreaStatusEventArgs e)
{
PublishAreaState(e.Area);
// Since the controller doesn't fire zone status change on area status change
// request update so armed, tripped, and secure statuses are correct
for (ushort i = 1; i < OmniLink.Controller.Zones.Count; i++)
{
clsZone zone = OmniLink.Controller.Zones[i];
if (zone.DefaultProperties == false && zone.Area == e.Area.Number)
OmniLink.Controller.Connection.Send(new clsOL2MsgRequestExtendedStatus(OmniLink.Controller.Connection, enuObjectType.Zone, i, i), HandleRequestZoneStatus);
}
}
private void HandleRequestZoneStatus(clsOmniLinkMessageQueueItem M, byte[] B, bool Timeout)
{
if (Timeout)
return;
clsOL2MsgExtendedStatus MSG = new clsOL2MsgExtendedStatus(OmniLink.Controller.Connection, B);
for (byte i = 0; i < MSG.ZoneStatusCount(); i++)
{
clsZone zone = OmniLink.Controller.Zones[MSG.ObjectNumber(i)];
zone.CopyExtendedStatus(MSG, i);
MqttClient.PublishAsync(zone.ToTopic(Topic.state), zone.ToState(), MqttQualityOfServiceLevel.AtMostOnce, true);
}
}
private void Omnilink_OnZoneStatus(object sender, ZoneStatusEventArgs e)
@ -390,11 +440,18 @@ namespace OmniLinkBridge.Modules
private void PublishAreaState(clsArea area)
{
MqttClient.PublishAsync(area.ToTopic(Topic.state), area.ToState(), MqttQualityOfServiceLevel.AtMostOnce, true);
MqttClient.PublishAsync(area.ToTopic(Topic.basic_state), area.ToBasicState(), MqttQualityOfServiceLevel.AtMostOnce, true);
}
private void PublishZoneState(clsZone zone)
{
MqttClient.PublishAsync(zone.ToTopic(Topic.state), zone.ToState(), MqttQualityOfServiceLevel.AtMostOnce, true);
MqttClient.PublishAsync(zone.ToTopic(Topic.basic_state), zone.ToBasicState(), MqttQualityOfServiceLevel.AtMostOnce, true);
if(zone.IsTemperatureZone())
MqttClient.PublishAsync(zone.ToTopic(Topic.current_temperature), zone.TempText(), MqttQualityOfServiceLevel.AtMostOnce, true);
else if (zone.IsHumidityZone())
MqttClient.PublishAsync(zone.ToTopic(Topic.current_humidity), zone.TempText(), MqttQualityOfServiceLevel.AtMostOnce, true);
}
private void PublishUnitState(clsUnit unit)

View file

@ -391,7 +391,7 @@ namespace OmniLinkBridge.Modules
case enuObjectType.Zone:
Controller.Zones.CopyProperties(MSG);
if (Controller.Zones[MSG.ObjectNumber].IsTemperatureZone())
if (Controller.Zones[MSG.ObjectNumber].IsTemperatureZone() || Controller.Zones[MSG.ObjectNumber].IsHumidityZone())
Controller.Connection.Send(new clsOL2MsgRequestExtendedStatus(Controller.Connection, enuObjectType.Auxillary, MSG.ObjectNumber, MSG.ObjectNumber), HandleRequestAuxillaryStatus);
break;

View file

@ -36,8 +36,15 @@ mqtt_server =
mqtt_port = 1883
mqtt_username =
mqtt_password =
# If you have multiple Omni Controllers you will want to change the
# mqtt_prefix and mqtt_discovery_name_prefix to prevent collisions.
# Prefix for MQTT state / command topics
mqtt_prefix = omnilink
# Prefix for Home Assistant discovery
mqtt_discovery_prefix = homeassistant
# specify a range of numbers like 1,2,3,5-10
# Prefix for Home Assistant entity names
mqtt_discovery_name_prefix =
# Specify a range of numbers like 1,2,3,5-10
mqtt_discovery_ignore_zones =
mqtt_discovery_ignore_units =
# device_class must be battery, door, garage_door, gas, moisture, motion, problem, smoke, or window

View file

@ -32,5 +32,5 @@ using System.Runtime.InteropServices;
// You can specify all the values or you can default the Build and Revision Numbers
// by using the '*' as shown below:
// [assembly: AssemblyVersion("1.0.*")]
[assembly: AssemblyVersion("1.1.1.0")]
[assembly: AssemblyFileVersion("1.1.1.0")]
[assembly: AssemblyVersion("1.1.2.0")]
[assembly: AssemblyFileVersion("1.1.2.0")]

View file

@ -55,7 +55,13 @@ namespace OmniLinkBridge
Global.mqtt_port = ValidatePort(settings, "mqtt_port");
Global.mqtt_username = settings["mqtt_username"];
Global.mqtt_password = settings["mqtt_password"];
Global.mqtt_discovery_prefix = settings["mqtt_discovery_prefix"];
Global.mqtt_prefix = settings["mqtt_prefix"] ?? "omnilink";
Global.mqtt_discovery_prefix = settings["mqtt_discovery_prefix"] ?? "homeassistant";
Global.mqtt_discovery_name_prefix = settings["mqtt_discovery_name_prefix"] ?? string.Empty;
if (!string.IsNullOrEmpty(Global.mqtt_discovery_name_prefix))
Global.mqtt_discovery_name_prefix = Global.mqtt_discovery_name_prefix + " ";
Global.mqtt_discovery_ignore_zones = ValidateRange(settings, "mqtt_discovery_ignore_zones");
Global.mqtt_discovery_ignore_units = ValidateRange(settings, "mqtt_discovery_ignore_units");
Global.mqtt_discovery_override_zone = LoadOverrideZone(settings, "mqtt_discovery_override_zone");

View file

@ -1,8 +1,8 @@
# OmniLink Bridge
Provides time sync, logging, web service API, and MQTT bridge for HAI/Leviton OmniPro II controllers
Provides time sync, logging, web service API, and MQTT bridge for HAI/Leviton OmniPro II controllers. Provides integration with Samsung SmarthThings via Web Service API and Home Assistant via MQTT.
## Download
You can download the [binary here](http://www.excalibur-partners.com/downloads/OmniLinkBridge_1_1_1.zip) or use docker to build an image from git.
You can download the [binary here](http://www.excalibur-partners.com/downloads/OmniLinkBridge_1_1_2.zip) or use docker to build an image from git.
## Requirements
- .NET Framework 4.5.2 (or Mono equivalent)
@ -53,7 +53,7 @@ You can download the [binary here](http://www.excalibur-partners.com/downloads/O
- cp OmniLinkBridge/OmniLinkBridge.ini /opt/omnilink-bridge
- vim /opt/omnilink-bridge/OmniLinkBridge.ini
3. Start docker container
- docker run -d --name="omnilink-bridge" -v /opt/omnilink-bridge:/config --net=host --restart unless-stopped omnilink-bridge
- docker run -d --name="omnilink-bridge" -v /opt/omnilink-bridge:/config -v /etc/localtime:/etc/localtime:ro --net=host --restart unless-stopped omnilink-bridge
4. Verify connectivity by looking at logs
- docker container logs omnilink-bridge
@ -86,12 +86,38 @@ To test the API you can use your browser to view a page or PowerShell (see below
## MQTT
This module will also publish discovery topics for Home Assistant to auto configure devices.
### Areas
```
SUB omnilink/areaX/state
string triggered, pending, armed_night, armed_night_delay, armed_home, armed_home_instant, armed_away, armed_vacation, disarmed
SUB omnilink/areaX/basic_state
string triggered, pending, armed_night, armed_home, armed_away, disarmed
PUB omnilink/areaX/command
string ARM_HOME, ARM_AWAY, ARM_NIGHT, DISARM, ARM_HOME_INSTANT, ARM_NIGHT_DELAY, ARM_VACATION
string(insensitive) arm_home, arm_away, arm_night, disarm, arm_home_instant, arm_night_delay, arm_vacation
```
### Zones
```
SUB omnilink/zoneX/state
string secure, not_ready, trouble, armed, tripped, bypassed
SUB omnilink/zoneX/basic_state
string OFF, ON
SUB omnilink/zoneX/current_temperature (optional)
int Current temperature in degrees fahrenheit
SUB omnilink/zoneX/current_humidity (optional)
int Current relative humidity
PUB omnilink/zoneX/command
string(insensitive) bypass, restore
```
### Units
```
SUB omnilink/unitX/state
PUB omnilink/unitX/command
string OFF, ON
@ -99,7 +125,10 @@ string OFF, ON
SUB omnilink/unitX/brightness_state
PUB omnilink/unitX/brightness_command
int Level from 0 to 100 percent
```
### Thermostats
```
SUB omnilink/thermostatX/current_operation
string idle, cool, heat
@ -132,14 +161,27 @@ string auto, on, cycle
SUB omnilink/thermostatX/hold_state
PUB omnilink/thermostatX/hold_command
string off, hold
```
### Buttons
```
SUB omnilink/buttonX/state
string OFF
PUB omnilink/buttonX/command
string ON
```
## Change Log
Version 1.1.2 - 2018-10-23
- Add min and max climate temperatures
- Update docker run command to use local time zone
- Improve area and zone MQTT support
- Add option to change MQTT prefix to support multiple instances
- Add detailed zone sensor and thermostat humidity sensor
- Add prefix for MQTT discovery entity name
- Request zone status update on area status change
Version 1.1.1 - 2018-10-18
- Added docker support
- Save subscriptions on change